Classification
Medical Device Class IIb
Dimensions
60 x 84 x 63 cm (wxhxd)
Weight
90 Kg
Chamber capacity
170 L
Power supply
Single-phase 220 V / 50Hz
Three-phase 380 V / 50Hz
Power consumption
2700 W (220 V) – 5600 W (380 V)
Connectivity
Included: USB and E-Memory software
Optional: Datalogger
CE Ref
DS 500 CDL
Download
Capacity
Thanks to the 170-litre washing chamber, it can accommodate up to four full loads of a 24-litre autoclave, equal to more than 140 instruments plus handpieces, turbines, scaler tips, burs.
Active drying
Drying, through the injection of hot air from several points inside the washing chamber, allows the complete elimination of water deposits on the outside and inside of the hollow-body instrument.
Powerful
The two rotating arms are arranged in such a way as to ensure that each level of the spacious washing chamber is reached by a powerful double flow of water – from above and below – for a total of 4 washing points.
Full optional
Equipped as standard with all the accessories needed to optimise loading: upper and lower loading trolley, instrument insert, 1 DIN basket, 2 inserts for 8-position trays and bur blocks.
The Eurosafe 170 is equipped with an integrated softener that allows the use of mains water and monitors the correct regeneration of the resins, giving a warning in the event of salt deficiency. The automatic dosing unit calibrates and injects the two detergent liquids, positioned outside the thermodisinfector, autonomously and without waste.
The thermodisinfector, at the end of each cycle, creates a file that can be transferred to a PC via USB, which reports all process data (time, temperature, cycle number), while also validating the load. In addition, thanks to optional accessories, data can be transferred via Ethernet connection or printed out thanks to the thermal printer.
Eurosafe 170 thermodisinfector
Pre-washing
This is carried out using cold water with the aim of removing organic substances and the most superficial and coarse dirt.
Washing
This is performed at temperatures between 50 and 65 °C, adding an enzymatic detergent to ensure perfect cleaning of the instruments.
Rinsing
This is done in order to remove any detergent residue
from the load used in the previous phase.
Thermodisinfection
This takes place through the combined action of hot water at an adjustable temperature of up to 95°C and a variable time of 1 to 10 minutes. During the heating phase, a second chemical agent is injected into the chamber, which prevents corrosion of the load and the forming of deposits, and also facilitates the subsequent drying phase.
Drying
The final stage of the process is achieved through effective air distribution within the chamber to obtain, when the device is opened, perfectly dry material ready for packaging.
Customisable
Eurosafe 60 has 20 pre-set cycles to better suit the washing needs of clinics. In addition, it is possible to create customised cycles with different combinations of time and temperature.
Above Standard
It ensures a minimum A0 value of 600 per thermodisinfection cycle. It is also possible to set a value higher and well above the standard, and monitor this parameter in real time via the display.
Inspectable
The transparent tempered glass door allows the contents to be monitored during washing and allows intervention in the event of incorrect positioning of the load inside the chamber.
Eco-friendly
It consumes only 1.7 kW and 12 litres of water per short cycle, while the automatic dispenser eliminates detergent waste.
Load capacity
A comprehensive range of accessories including loading baskets, inserts, baskets and adapters simplifies the operator’s work and enables excellent cleaning, thermodisinfection and drying performance, maximising loading capacity and minimising waste.
Optimising spaces
Designed to utilise every centimetre of the washing chamber thanks to the two mirror-image load levels – upper and lower – that ensure easy load distribution.
Integrable
he numerous possible load combinations adapt to the needs of every clinic and allow the Eurosafe 60 to be configured to meet each individual need. The available accessories meet the needs of all clinics working in the dental, maxillofacial surgery, oral surgery, orthodontics and general medicine fields.
Traceability
Full and safe control
of the procedures
Eurosafe 170 allows you to track of all thermodisinfection cycles performed, saving the data on USB. They can also be transferred to a PC via Ethernet connection or printed on thermal paper using the optional accessories.
E-Memory
E-Memory is the software for the complete archiving, management and traceability of all sterilization cycles and data directly on a PC. This application can automatically, semi-automatically or manually capture data from the sterilization process and save it directly to the computer. This data can be easily organised, searched, printed and emailed.